Hydrotech Aquafier® Specifications:
Lead
Reduction
Influent
Avg mg/l
Effluent
Avg mg/l
Avg
% Rej
Effluent
Max mg/l
Min
% Rej
MCL
mg/l
Low Level pH & Alkalinity 0.166 0.002 99% 0.002 99% 0.015
High Level pH & Alkalinity 0.136 0.002 99% 0.002 99% 0.015
Mechanical
Filtration
Influent Average
per milliliter
Effluent
Average/ml
Average
% Rej
Effluent
Maximum/ml
Minimum
% Rej
NSF Required
% Rejection
Cycts 102,750 5 >99.99% 5 >99.99% 99.95%
Turbidity 12 NTU 0.17 NTU 98.6% 0.19 NTU 98.4% 1.0 NTU
Particulates 31 x 106 23,740 >99.99% 81,000 99.7% Class l (85%)
NOTE: Certification for Cysts reduction includes Cryptosporidium and Giardia lamblia.
VOLATILE ORGANIC CHEMICALS (VOCs)
Refer to Performance Data Sheet for individual contaninant performance data.
Aesthetics Influent Average
per milliliter
Effluent
Average/ml
Average
% Rej
Effluent
Maximum/ml
Minimum
% Rej
NSF Classification Required
% Rejection
Chlorine 1.47 0.07 95% 0.1 93% Class l (75%)
Service Flow Rate
1.9 Liter/minute (0.5 gallon/minute)
Actual rate varies according to water temperature, pressure, TDS levels, and customer usage.
System Capacity
6615 Liters (1750 gallons)
with Faucet Smartap® Flow Monitor
6615 Liters (1750 gallons)
with Pushbutton Smartap® Flow Monitor
3969 Liters (1050 gallons)
without Flow Monitor
Conditions for System Use
Carbon Filter Types: Pb1 & 5a
Source Water Supply Profile
Application Guidelines
Community/Private Chlorinated/NonChlorinated Use this drinking water system on potable water supply only.

CAUTION: Do not use this system where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system.

System Pressure 173-863 kPa (25-125 psig)
Temperature 4°-38° C (40°-110° F)

NOTE: System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Back