Stage One
Sediment Filter, 5-Micron Polyspun Cartridge, 2 1/2” dia. x 20" long
Stage two
Activated Carbon Block Filter
5 Micron, 2 1/2” dia. x20" long
Stage Three
Activated Carbon Block Filter
5 Micron, 2 1/2” dia. x20" long
booster pump
Diaphragm pump with pressure by-pass with low voltage DC motor
Stage Four
Up to four 100 GPD Hi-Flux Reverse Osmosis Membranes

Stage Five

In-Line post filter, 10-micron granular activated carbon, 2 1/2" dia., 14" long (Option-replace carbon post filter with deionizer cartridge.)

 

 

Restaurant Drinking Water and Ice Supply

5-Stage Reverse Osmosis Filtration makes clean, good tasting, odor-free water from 150-GPD to 350-GPD.

Features







Auto Shut-Off valve (Conserves water)
Flow Restrictor – modified capillary
Long Reach, Non-airgap Faucet
Feed water connector – Threaded Inlet Adapter with Metal Ballvalve Drain Clamp
3/8 Inch Flexible Polyethylene Tubing w/Quick Connect Fittings
   
Up to four high capacity RO membranes are used in series to provide the required water rate. It is supplied with a 14-gallon pressurized tank which holds 9-gallons of water. Two tanks may be used to increase the reserve to 18-gallons. The RO technology removes an average of 95% of the TDS. To further decrease the salt content, a de-ionizer cartridge can be installed as a post-filter. The five stages are described in the table below.

A booster pump is installed in the system to provide water pressure of 85 psi to the membranes. To reduce wear on the pump, it is installed after the the pre-filters. A pressure switch in the line to the tank will turn on the pump when the tank pressure is 25 psi, and off at 40 psi. and is also adjustable.

An optional stand can be provided. Made of powder coated steel, it bolts to the underside of the bracket, providing a floor standing unit.

Specifications
Shipping Weight: 65-80 lb.
Dimension: 13 1/2" L x 7.5" W x 40" H
Tank 15 3/4" dia. x 22 1/2" H
Booster Pump: 24-36 volt DC flow through diaphram pump with 110VAC/ 24-36VDC60hz transformer

Conditions of Use
• Water Must be microbiologically safe
• Temperature, 40 -100 degrees F
• pH Range, 3 to 11
• Feed pressure, 20 to 100 psig
• Maximum TDS, 1500 PPM
• Turbidity, less than 1.0 NTU
ed

AVAILABLE OPTIONS
350 GPD clean water rate
250 GPD clean water rate
150 GPD clean water rate
Optional Floor Stand
Optional de-ionizing stage


PWM-350
PWM-250
PWM-150
add /FS
add /DI

Replacement Filters


RO membrane
Sediment
Carbon Block
Post Carbon
PWM-150
PWM-250
PWM-350
SF-4014
CF-4015 x 2
IF-4011
MH-4206 x 2
MA-4205 x 3
MA-4205 x 4